      System Configuration
    • LED transillumination
    • APLLC Xe illumination
    • Fast shutter
    • 10-position ND filter wheel
    • 10-position EX filter wheel
    • 6-position EM filter wheel
    • Optical fiber
    • Fiber Optical Module (FOM)
    • IX-71 microscope base
    • Custom DeltaVision Quad filter set
    • 60x objective/1.42NA
    • 50 mm long travel stage
    • CoolSnap HQ2 Camera
    • DeltaVision microscopy platform
    • DeltaVision electronics rack
    • Dual processor, dual core computer 1TB RAID5
    • 24" monitor
    • Backlit keyboard, laser mouse
    • Data Management Solution (DMS)
      Instrument Control
    • Instrument Control (IC) computer
    • Microscope Interface Chassis (MIC)
    • Lamp power supplies
    • NanoMotion® III position control
    • Single rackmounted IC/MIC enclosure design
    • Faster performance
      Stage Specifications
      Z axis
    • Absolute accuracy
      - < 0.6 um per 13 um Z scan
      - < 2.0 um per 100 um Z scan
    • Out-of-axis motion
      - < 0.6 um per 13 um Z scan (< 0.3 um typical)
    • Step resolution
      - 5 nm (theoretical)
    • Unidirectional repeatability
      - < 0.2 um (< 0.1 um typical)
    • Maximum travel
      - 1 mm
    • Typical speed
      - 1000 um/sec
      XY axes
    • Absolute accuracy
      - < 10.0 um per 25 mm of travel
    • Unidirectional repeatability
      - < 0.4 um per axis (< 0.2 um typical)
    • Step resolution
      - 20 nm (theoretical)
    • Maximum travel
      - 25 mm X, Y (25 x 25 stage)
      - 25 mm (X) x 50mm (Y) (25 x 50 stage)
    • Typical speed
      - 2000 um/sec
      Illumination
    • 250 W Xe Fluorescence Illumination long-life bulb
      - More stable illumination for longer continuous experiments
      - Increased illumination for DAPI, GFP, Cy5
    • LED Transillumination
      - Better light concentration
      - Improved reliability
      - Faster on/off cycles
      - No mechanical shutters
      - Improved color balance
      Software
    • softWoRx 3.6.0
    • softWoRx Suite visualization and analysis
    • Data Management Server (DMS)
      - Image data management
      - Built on Open Microscopy Environment (OME) standards in collaboration with Glencoe Software, Inc.
    • Actions
      - Enables multi-channel PK experiments
      - Enables 3-D PK experiments
      - Optimize experiments for your applications
    • Multiplexed Wavelengths
      - Experiment design
      - Interleaved averaging
    • Enhanced Queue Management
      - System level queue
      - Deconvolution, volume rendering, movie creation
      - Chained events
    • Ratio Imaging
      - Bio-sensors
      - Calcium (Fura-2)
      - FRET Biosensors
      - On-the-fly visualization
      - Post-processing and analysis
      Workstation
    • Dual processor, dual core
    • 1TB RAID5
    • Multi-threaded deconvolution and rendering
    • More than 5X faster than previous version
    • CentOS EL4.0
    • USB drive support
    • DVD-R support
    • 24” LCD monitor
    • Backlit keyboard, laser mouse
      Options
    • Quantifiable Laser Module (QLM)
    • TIRF (includes QLM)
    • Live-cell Filter Set
    • WeatherStation environmental chamber
    • Cascade2 Camera
    • Standalone Workstation
    • Multiplexed Wavelengths Imaging
      - EGFP/mCherry Polychroic and Dual Band EM
      - CFP/YFP Polychroic and Dual Band EM
      Upgrades
    • Dual Processor, dual core computer 5TB RAID5
    • 30” monitor

    personalDV Specifications

    ( Specifications subject to change )
      System Configuration
    • White LED transillumination
    • APLLC Xe illumination
    • Fast shutter
    • 10-position ND filter wheel
    • 10-position EX filter wheel
    • 6-position EM filter wheel
    • Optical fiber
    • Fiber Optic Module (FOM)
    • IX-71 microscope base
    • Custom DeltaVision Quad filter set
    • 60x objective/1.42NA
    • Stackable IC/MIC
    • Dual processor tower computer, 400GB
    • 25 mm stage
    • CoolSnap ES2 Camera (PCI)
    • Benchtop microscopy isolation platform
    • 19" monitor
    • Backlit keyboard, laser mouse
      Instrument Control
    • Instrument Control (IC) computer
    • Microscope Interface Chassis (MIC)
    • Lamp power supplies
    • NanoMotion® III Stage Control
    • Single enclosure design
    • Faster performance
      Stage Specifications
      Z axis
    • Absolute accuracy
      - < 0.6 um per 13 um Z scan
      - < 2.0 um per 100 um Z scan
    • Out-of-axis motion
      - < 0.6 um per 13 um Z scan (< 0.3 um typical)
    • Step resolution
      - 5 nm (theoretical)
    • Unidirectional repeatability
      - < 0.2 um (< 0.1 um typical)
    • Maximum travel
      - 1 mm
    • Typical speed
      - 1000 um/sec
      XY axes
    • Absolute accuracy
      - < 10.0 um per 25 mm of travel
    • Unidirectional repeatability
      - < 0.4 um per axis (< 0.2 um typical)
    • Step resolution
      - 20 nm (theoretical)
    • Maximum travel
      - 25 mm X, Y (25 x 25 stage)
      - 25 mm (X) x 50mm (Y) (25 x 50 stage)
    • Typical speed
      - 2000 um/sec
      Illumination
    • 250 W Xe Fluorescence Illumination Long-life bulb
      - 10X longer bulb life (>1000 hours)
      - More stable illumination for longer continuous experiments
      - Increased illumination for DAPI, GFP, Cy5
    • LED Transillumination
      - Better light concentration
      - Improved reliability
      - Faster on/off cycles
      - No mechanical shutters
      - Improved color balance
      Software
    • softWoRx 3.6.0
    • Actions
      - Optimize experiments for your applications
    • Ratio Imaging
      - Bio-sensors
      - Calcium (Fura-2)
      - FRET Biosensors
      - On-the-fly visualization
      - Post-processing and analysis
    • Enhanced Queue Management
      - System level queue
      - Deconvolution, Volume Rendering, Movie creation
      - Chained events
    • Optional Data Management Solution (DMS) support
      - Image data processing, management and storage
      - Built on Open Microscopy Environment (OME) standards in collaboration with Glencoe Software, Inc.
    • Optional Multiplexed Wavelengths Imaging support
      - Experiment design
      - Interleaved averaging
      Workstation
    • Dual processor
    • 400 GB storage
    • High capacity, high speed
    • Multi-threaded deconvolution and rendering
    • More than 5X faster than previous version
    • CentOS EL4.0
    • USB drive support
    • DVD-R support
    • 19” LCD monitor
    • Backlit keyboard, laser mouse
      Options
    • WeatherStation environmental chamber
    • Live-cell filter set
    • softWoRx Suite visualization and analysis software
    • Standalone Workstation
    • Data Management Solution (DMS)
    • Multiplexed Wavelengths Imaging
      - EGFP/mCherry Polychroic and Dual Band EM
      - CFP/YFP Polychroic and Dual Band EM
      Upgrades
    • 25 mm x 50 mm long travel stage
    • CoolSnap HQ2 Camera
    • DeltaVision Isolation Table
    • 24" monitor
  • Applied Precision, DeltaVision and softWoRx are registered trademarks of Applied Precision, Inc.
    All other trademarks are the property of their respective owners.


    © 2008 Applied Precision, Inc